Pathway DMX QConnect Software for CR Manual Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Software Pathway DMX QConnect Software for CR Manual herunter. Pathway DMX QConnect Software for CR Manual User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Pathway Connectivity

DMXQConnect for DMXPathfinder CR User Guide Version 2.2 August 2005 Pathway Connectivity 1439 17th Avenue SE, Unit 103 Calgary, AB,

Seite 2 - CONTENTS

DMXQConnect for CR - User Guide System Requirements and Installation 7 COMMUNICATIONS SETUP 1. Determine which COM port your computer will utilize f

Seite 3

DMXQConnect for CR - User Guide System Requirements and Installation 8 ensure that the BACK/NORM switch on the Master Control Module is set to NORM.

Seite 4 - INTRODUCTION

DMXQConnect for CR - User Guide System Requirements and Installation 9 10. Once the PC-to-Pathfinder communications function is working correctly as

Seite 5 - WHAT IS DMX Q-CONNECT?

DMXQConnect for CR - User Guide System Requirements and Installation 10 The window should now close and a moving bar graph will appear briefly under

Seite 6

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 11 Chapter 3: Getting Familiar with DMXQConnect SUMMARY Follow this Chapter to

Seite 7

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 12 PATCHING First go to the Patch Mode pane at the far right of your screen. Mak

Seite 8 - YSTEM REQUIREMENTS

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 13 access to the usual Windows commands of Undo, Cut, Copy, Paste and Delete, m

Seite 9 - INSTALLING DMXQCONNECT

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 14 TALKBACK If you are using IPS dimmers, Wybron Scrollers or any othe receiving

Seite 10 - COMMUNICATIONS SETUP

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 15 Mode pane. The bar graph will confirm, as before, that the file transfer funct

Seite 11

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 16 Select View from the main menu. Choose DMXPathfinder Options. Click on the

Seite 12

DMXQConnect for CR - User Guide Contents CONTENTS INTRODUCTION... 1 WELCOME TO DMXQCONN

Seite 13

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 17 There are two tabs, Show Specific and Defaults. The values entered under the D

Seite 14 - EW SHOW

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 18 erase all information contained in the Show Specific tab so that the Default va

Seite 15 - ICONS & DESCRIPTIONS

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 19 SOURCE CONFIGURATION Next we will assign working names to the various DMX sourc

Seite 16 - N-PATCH A STATION

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 20 appear. Click Yes to confirm. Continue until all Sources in the table have be

Seite 17 - ALKBACK

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 21 CONNECTED STATIONS DISPLAY To see which stations are connected to a specific

Seite 18 - ETTING UP THE SYSTEM

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 22 COMMAND LINE As an alternative to the “drag and drop” style of patching, you c

Seite 19 - UNIVERSE

DMXQConnect for CR - User Guide Getting Familiar with DMXQConnect 23 OPENING A DIFFERENT SHOW You may wish to work with a show other than the one t

Seite 20

DMXQConnect for CR - User Guide Command Reference 24 Chapter 4: Command Reference SUMMARY This Section describes the function and use of DMXQConne

Seite 21

DMXQConnect for CR - User Guide Command Reference 25 Use the standard Windows 95 file management conventions to specify where you want the archive s

Seite 22 - SOURCE CONFIGURATION

DMXQConnect for CR - User Guide Command Reference 26 Splash: This refers to the initial screen and graphic seen when DMXQConnect is first started.

Seite 23 - TATION CONFIGURATION

DMXQConnect for CR - User Guide Contents SYSTEM HEALTH CHECK ... 30 FILE TRANSFER ERRORS...

Seite 24 - RINTED REPORTS

DMXQConnect for CR - User Guide Command Reference 27 Show Command Line & Show Status Bar You can choose to have the Command Line and Status Line

Seite 25 - ACKUP YOUR DATA!

DMXQConnect for CR - User Guide Command Reference 28 Click Yes to confirm. Note: Only the last Source in the table can be deleted with each Delete

Seite 26 - DIFFERENT SHOW

DMXQConnect for CR - User Guide Command Reference 29 To add a new Universe, click the Add New button to clear Universe and Description boxes at the

Seite 27 - ILE MENU

DMXQConnect for CR - User Guide Diagnostics and Troubleshooting 30 Chapter 5: Diagnostics and Troubleshooting SUMMARY This Chapter explains how to

Seite 28 - IEW MENU

DMXQConnect for CR - User Guide Diagnostics and Troubleshooting 31 DMXPathfinder on the received file to ensure data integrity. The response messag

Seite 29

DMXQConnect for CR - User Guide Diagnostics and Troubleshooting 32 out “deep” testing of the DMXPathfinder crosspoint electronics, the terminal wind

Seite 30 - CONFIGURE MENU

DMXQConnect for CR - User Guide Diagnostics and Troubleshooting 33 test mode. To do a continuity test for a given output line, say Station #15, fo

Seite 31

DMXQConnect for CR - User Guide Diagnostics and Troubleshooting 34 the Frame or Master Control Module, and problems that affect every line in the sy

Seite 32

DMXQConnect for CR - User Guide Diagnostics and Troubleshooting 35 Pressing "m" toggles the test mode between manual and automatic. In

Seite 33 - ILE TRANSFER ERRORS

DMXQConnect for CR - User Guide Diagnostics and Troubleshooting 36 plugged in to the I/O channel indicated on the display. Re-run the test on a kno

Seite 34 - OOPBACK TEST

DMXQConnect for CR - User Guide Introduction 1 INTRODUCTION WELCOME TO DMXQCONNECT! This User Guide is intended to familiarize you with the setup a

Seite 35 - RAPHICAL SCREEN METHOD

DMXQConnect for CR - User Guide Diagnostics and Troubleshooting 37 letter keyboard commands for various functions. Three menu choices are shown: Sy

Seite 36

DMXQConnect for CR - User Guide Index 38 INDEX [ [*] key · 22 [/] key · 22 [@] key · 22 [+] key · 22 [Caps Lock] key · 37 [Delete] key · 22 [Enter]

Seite 37 - ERMINAL WINDOW METHOD

DMXQConnect for CR - User Guide Index 39 File Menu · 24 File Transfer Errors · 30 Frame Control module · 32 Frame Control Module · 37 G ground loop

Seite 38

DMXQConnect for CR - User Guide Index 40 Show Command Line & Show Status Bar · 27 Show names · 24 show patches · 24 Show Specific · 17, 18, 28 s

Seite 39 - CODES AND SERIAL NUMBERS

DMXQConnect for CR - User Guide About DMXQConnect 2 Chapter 1: About DMXQConnect QUICK START Like most users of new lighting control equipment,

Seite 40 - CCESS CODE INPUT

DMXQConnect for CR - User Guide About DMXQConnect 3 matrix devices that are commonly used in digital telephone switching systems carry out the patc

Seite 41 - *] key · 22

DMXQConnect for CR - User Guide About DMXQConnect 4 Launching DMXQConnect, the user is presented with a combination status screen and work area m

Seite 42

DMXQConnect for CR - User Guide System Requirements and Installation 5 Chapter 2: System Requirements and Installation SUMMARY: This Chapter descr

Seite 43

DMXQConnect for CR - User Guide System Requirements and Installation 6 DMXPathfinder rack. Any COM port in the range of 1 to 4 will work. DMXQConn

Kommentare zu diesen Handbüchern

Keine Kommentare